  Datasheet File OCR Text:
  technical d at asheet pmr panel mount power supply 5v 300w 1 phase / pmr - 5v320wd a all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com (october 2014 , rev. 00) 1 pm r highlights & features ? universal ac input voltage ? full corrosion resistant aluminium case and chassis ? built - in active pfc and conforms to harmonic current iec/en 61000 -3 - 2, class a and class d ? low profile design for 1u installation ? high reliability with fanless design ? built - in dc ok relay contact and redundancy operation (pmr -5 v320wdba and pmr - 5 v320wdca) safety standards cb certified for worldwide use model number: pm r -5 v320 w d ? a unit weight : 0 . 86 kg dimensions (l x w x d): 215 x 115 x 3 0 mm general description the pmr -5 v320wd ?a offers nominal output voltage of 5 v with a wide operating temperature range from - 2 0c to +70c and can withstand shock and vibration according to iec 60068 - 2. the product comes with universal ac input voltage range at 88vac to 264vac. at only 30mm height and encased in a full corrosion resistant aluminium casing, the pmr series is made for in stallation in narrow space while its built - in active pfc circuit provides high power factor values and conforms to harmonic current emission according to iec/en 61000 -3 - 2, class a and class d . model information pm r panel mount power supply model number input v oltage range output v oltage output cur r ent pm r -5 v320 w d ? a 8 8 - 264vac 5vdc 60.0a model numbering cc code pm r ? 5 v 32 0w d panel mount product series r ? standard rack type series (1u) output voltage output power (320w series model) package type d ? enclosed with out fan connector type a ? terminal block b ? terminal block (parallel connection )* g ? front face* c ? front face (parallel connection )* variable a ? coating *options
technical d at asheet pmr panel mount power supply 5v 300w 1 phase / pmr - 5v320wd a all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com (october 2014 , rev. 00) 2 specifications input ratings / characteristics nominal input v oltage 100-24 0 v ac input v oltage range 8 8 - 264vac nominal input f r equency 50- 60hz input f r equency range 47- 63hz input cur r ent < 5.0 0a @ 115vac, < 2.50a @ 230vac ef ficiency at 100% load pmr -5v 320wd a a 86.0 % typ. @ 115vac, 88.0 % typ. @ 230vac pmr -5v 320wd g a pmr -5v 320wd b a 85 .0% typ. @ 115vac, 87 .0% typ. @ 230vac pmr -5v 320wd c a max inrush cur r ent (cold start) < 20a @ 115vac, < 40a @ 230vac power factor at 100% load 0.98 typ. @ 115vac, 0.95 typ. @ 230vac leakage cur r ent < 1ma @ 240vac output ratings / characteristics nominal output voltage 5 vdc output voltage tolerance 1 % (initial set point tolerance from factory ) for pmr - 5 v320wd a a and pmr - 5 v320wd g a output voltage adjustment range pmr -5v 320wd a a 4.50 - 5.50 vdc pmr -5v 320wd g a output voltage range pmr -5v 320wd b a 4.75 - 5.25 vdc ( no potentiometer ) pmr -5v 320wd c a output current 60.0a output power 300 w line regulation 0.5% typ. (@ 115vac & 230vac, 100% load) load regulation 1.0% typ. (@ 115vac & 230vac, 0 - 100% load) for pmr - 5 v320wd a a and pmr - 5 v320wd g a pard (20mhz) < 150mvpp @ 25c < 300mvpp @ - 2 0c rise time 100 ms typ. @ 115vac & 230vac (100% load) start - up time 3000ms typ. @ 115vac, 1500ms typ. @ 230vac (100% load ) hold - up time 8ms typ. @ 115vac & 230vac dynamic response (overshoot & undershoot o/p voltage) 1500mvpp @ 10 - 50% load and 50- 100% load start - up with capacitive loads 8,000f max functional* parallel connection ? for n+1 connection, note that n 4 (difference of coupling impedance for each power supply must be < 5m? in redundancy connection). ? the total output power shall be < n 80% rated power. dc ok relay contact 5v / 0.1a the relay is usually open when the output is normal. * for pmr - 5 v320wd b a and pmr - 5 v320wd c a .
technical d at asheet pmr panel mount power supply 5v 300w 1 phase / pmr - 5v320wd a all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com (october 2014 , rev. 00) 3 mechanical case chassis / cover aluminium dimensions (l x w x d) 215 x 115 x 3 0 mm unit weight 0. 8 6 kg indicator green led (dc ok) cooling system convection terminal pmr -5 v320wd a a m3.5 x 9 pins (rated 300v/15a) pmr -5 v320wd g a m3.5 x 9 pins (rated 300v/20a) pmr -5 v320wd b a m3.5 x 9 pins (rated 300v/15a) pmr -5 v320wd c a m3.5 x 9 pins (rated 300v/20a) wire awg 14 -12* noise (1 meter from power supply) sound pressure level (spl) < 25 dba *only use wire that can withstand operating temperature of more than 125c. environment surrounding air temperature operating -2 0c to + 7 0 c (cold start at - 4 0c) storage -4 0 c to + 85 c power de - rating > 40 c de - rate power by 1 % / c , > 50c de - rate power by 1.5% / c < 11 0 vac de - rate power by 1 % / 1 v operating humidity 5 to 95 % rh (non - condensing) operating altitude 0 to 5 ,000 meters shock test (non - operating) iec 60068 -2 - 27, half sine: 5 0g for a duration of 11 ms, 3 shocks for each 3 direction s vibration ( non - operating) iec 60068 -2 -6, random: 5hz to 500hz (2.09grms); 2 0 min per axis for all x, y, z direction pollution degree 2 protections overvoltage 5. 75-6. 5 0 v, hiccup mode , non - latching ( auto - recovery ) overload / overcurrent 105- 150% , hic c up mode, non - latching (auto - recovery) over temperature hiccup mode, non - latching (auto - recovery) short circuit hiccup mode, non - latching (auto - recovery) protection against shock class i with pe* * connection * * pe: primary earth reliability data mtbf > 7 00,000 hrs. as per telcordia sr -332 i/p: 100vac, o/p: 100% load, ta: 35c expected cap life time 10 years (115vac & 230vac , 50% load @ 40c )
technical d at asheet pmr panel mount power supply 5v 300w 1 phase / pmr - 5v320wd a all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com (october 2014 , rev. 00) 4 safety standards / directives electrical safety tuv bauart to en 60950 - 1, ul/cul recognized to ul 60950 -1 and csa c22.2 no. 60950 -1 (file no. e131881) , cb scheme to iec 60950- 1 , ccc to gb 4943 ce in conformance with emc directive 2004/108/ec and low voltage directive 2006/95/ec material and parts rohs directive 2011/65/eu compliant galvanic isolation input to output 3 .0kvac input to ground 2.0kvac output to ground 0 .5kvac emc emc / emissions cispr 22, en 55022, fcc title 47: class b immunity to en 55024 electrostatic discharge iec 61000 -4 -2 level 4 criteria a 1) air discharge: 15kv contact discharge: 8kv radiated field iec 61000 -4 -3 level 3 criteria a 1) 80mhz - 1ghz, 10 v/m with 1khz tone / 80% modulation electrical fast transient / burst iec 61000 -4 -4 level 3 criteria a 1) 2kv surge iec 61000 -4 -5 level 3 criteria a 1) common mode 2) : 2kv differential mode 3) : 1kv conducted iec 61000 -4 -6 level 3 criteria a 1) 150khz - 80mhz, 10vrms power frequency magnetic fields iec 61000 -4 -8 criteria a 1) 10a/meter voltage dips iec 61000 -4 -11 100% dip; 1 cycle (20ms); self recoverable low energy pulse test (ring wave) iec61000 - 4 -12 level 3 criteria a 1) common mode 2) : 2kv differential mode 3) : 1kv harmonic current emission iec/en 61000 -3 - 2, class a and class d voltage fluctuation and flicker iec/en 61000 -3 -3 1) criteria a: normal performance within the specification limits 2) asymmetrical: common mode (line to earth) 3) symmetrical: differential mode (line to line)
technical d at asheet pmr panel mount power supply 5v 300w 1 phase / pmr - 5v320wd a all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com (october 2014 , rev. 00) 5 block diagram device description s 1 ) input & output terminal block connector 2 ) dc voltage adjustment potentiometer (option) 3 ) dc ok control led (green) 4 ) dc ok relay contact (option) pmr - 5 v320wd a a, pmr - 5 v320wd b a: terminal block pmr - 5 v320wd g a, pmr - 5 v320wd c a: front face
technical d at asheet pmr panel mount power supply 5v 300w 1 phase / pmr - 5v320wd a all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com (october 2014 , rev. 00) 6 dimensions l x w x d: 215 x 115 x 3 0 mm ( pmr -5 v320wd a a, pmr -5 v320wd b a: terminal block )
technical d at asheet pmr panel mount power supply 5v 300w 1 phase / pmr - 5v320wd a all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com (october 2014 , rev. 00) 7 l x w x d: 215 x 115 x 50 mm ( pmr -5 v320wd g a, pmr -5 v320wd c a: front face )
technical d at asheet pmr panel mount power supply 5v 300w 1 phase / pmr - 5v320wd a all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com (october 2014 , rev. 00) 8 engineering data de - rating output de - rating vs. input voltage note 1 . power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in fig. 1. 2 . if the output capacity is not reduced when the surrounding air temperature >40 c, the device will run into over temperature protection. when activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in workin g condition. 3 . in order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm with adjacent units while the device is in operation. 4 . depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5 . if the device has to be mounted in any other orientation, please do not hesitate to contact info@deltapsu.com for more details. fig. 1 de - rating for vertical and horizontal mounting orientation > 40c de - rate power by 1% / c, > 50c de - rate power by 1.5% / c ? no output power de - rating for the input voltage from 110vac to 264vac
technical d at asheet pmr panel mount power supply 5v 300w 1 phase / pmr - 5v320wd a all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com (october 2014 , rev. 00) 9 assembly & installation ? side mounting: fig. 2 and fig. 3 show the mounting hole locations for power supply assembly onto a metal mounting surface. the power supply shall be mounted on minimum of 2 mounting holes using m4 screw of maximum 5 mm length (refer to fig. 4). this is to maintain a safety distance between the screw and internal components. ? base mounting: fig. 2 and fig. 3 show the mounting hole locations for power supply assembly onto a metal mounting surface. the power supply shall be mounted on minimum of 4 mounting holes using m4 screw of maximum 4mm length (refer to fig. 4). this is to maintain a safety distance between the screw and internal components. ? connector ? this surface belongs to customer?s end system or panel where the power supply is mounted. base mounting (horizontal) base mounting (vertical) fig. 2 recommended mounting orientations ? use flexible cable (stranded or solid) of awg no. 14 - 12. the input/output connectors? allowable current is 23a max per pin. user should calculate and select the suitable wire specification (type/quantity/diameter) according to actual output current. the torque at the connector shall not exceed 13kgf.cm. the insulati on stripping length should not exceed 0.275? or 7mm. ? recommended mounting torque of the product and its mounting accessories is 9~12kgf.cm. fig. 4 assembly reference ? only use m4 screw ?ppwkurxjkwkhedvhprxqwlqjkrohvdw ? . this is to keep a safe distance between the screw and internal components. ? only use m4 screws . this is to keep a safe distance between the screw and internal components. fig. 3 mounting hole locations
technical d at asheet pmr panel mount power supply 5v 300w 1 phase / pmr - 5v320wd a all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com (october 2014 , rev. 00) 10 safety instructions ? if user?s mounting orientation is not according to the recommended mounting orientations, please consult delta for further information. ? to ensure sufficient convection cooling, always maintain a distance of 20mm from ventilated surfaces while the device is in operation. ? the device is not recommended to be placed on low thermal conductive surface. for example, plastics. ? t he enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. do not touch the devic e while it is in operation or immediately after power is turned off. risk of burning! ? do not touch the terminals while power is being supplied. risk of electric shock. ? prevent any foreign metal, particles or conductors from entering the device through the openings during installation. it may cause electric shock, safety hazard, fire, and/or product failure. ? warning: when connecting the device, secure earth connection before connecting l and n. when disconnecting the device, remove l and n connections before removing the earth connection. the power supply must be mounted by metal screws onto a grounded metal surface. it is highly recommended that the earth terminal on the connector be connected to the grounded metal surface. accessories lm- 01: top fixing bracket this bracket is used to fix the power supply onto a flat surface from the top.
technical d at asheet pmr panel mount power supply 5v 300w 1 phase / pmr - 5v320wd a all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com (october 2014 , rev. 00) 11 functions start - up time the time required for the output voltage to reach 90% of its set value, after the input voltage is applied. rise time the time required for the output voltage to change from 10% to 90% of its set value. hold - up time hold up time is the time when the ac input collapses and output voltage retains regulation for a certain period of time. the time required for the output to reach 95% of its set value, after the input voltage is removed. graph illustrating the start - up time, rise time, and hold- up time inrush current inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. for ac input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied ac voltage. this peak value decreases exponentially during subsequent cycles of ac voltage. dynamic response t he power supply output voltage will remain within 1500mvpp of its steady state value, when subjected to a dynamic load from 1 0 to 50% and 50 to 100% of its rated current. ? 1 0 to 50% load ? 50 to 100% load
technical d at asheet pmr panel mount power supply 5v 300w 1 phase / pmr - 5v320wd a all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com (october 2014 , rev. 00) 12 overload & overcurrent protections the power supply?s overload (olp) and overcurrent (ocp) protections will be activated when output current exceeds 1 05-1 50 % of i o (max load). in such occurrence, the v o will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into ?hiccup mode? (auto - recovery). the power supply will recover once the fault condition of the olp and ocp is re moved and i o is back within the specifications. it is not recommended to prolong the duration of i o when it is < 105% but >100%, since it may cause damage to the psu. short circuit protection the power supply?s output olp/ocp function also provides protection against short circuits. when a short circuit is applied, the output current will operate in ?hiccup mode?, as shown in the illustration in the olp/ocp section on this page. the power supply will return to normal operation after the short circuit is removed. overvoltage protection the power supply?s overvoltage circuit will be activated when its internal feedback circuit fails. the output voltage shall not exceed its specifications defined on page 3 under ?protections?. over temperature protection as mentioned above, the power supply also has over temperature protection (otp). in the event of a higher operating temperature at 100% load, the power supply will run into otp when the operating temperature is beyond what is recommended in the de- rating graph. when activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de - rating graph.
technical d at asheet pmr panel mount power supply 5v 300w 1 phase / pmr - 5v320wd a all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com (october 2014 , rev. 00) 13 others delta rohs compliant restriction of the usage of hazardous substances the european directive 2011/65/eu limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants pbb and pbde for th e use in electrical and electronic equipment. rohs is the abbreviation for ?restriction of the use of certain hazardous substances in electrical and electronic equipment?. this product conforms to this standard. conformal coa ting the protective coating technology delta electronics group has designed the perfect dipping technique which penetrates everywhere including under device, and prevents leakage. the conformal coating dipping can be applied to pcbas or circuit board. the coating preserves the performance of pr ecision electronic primarily by preventing ionizable contaminants such as salt from reaching circuit nodes, where the material slumps around sharp edges. this can be a problem especially in highly conversing atmosphere. pfc ? norm en 61000 - 3 - 2 line current harmonic content typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. in industrial environment, complying with en 61000 - 3 - 2 is only necessary under special conditions. complying to this standard can have some technical drawbacks, such as lower efficiency as well a s some commercial aspects such as higher purchasing costs. frequently, the user does not profit from fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific application.


▲Up To Search▲   

 
Price & Availability of PMR-5V320WDXA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X